Group
Parameter
Number
Name
Setting Range
Factory
Value
User
settings
03-00
P.83
DI1 function selection
35: MPO (in “external mode” the manually operation cycle
mode is chosen.)
0
36: TRI (triangle wave function is chosen)
37: GP_BP (Automatic switchover frequency between
inverter and commercial power-supply operation.)
38: CS (Manual switch to commercial power supply)
39: STF/STR +STOP (The motor has a reverse rotation when
the RUN signal is on. When the RUN signal is off, stop
the motor and then run the motor for forward rotation.
40: P_MRS (the inverter output instantaneously stops, The
MRS is pulse signal input)
41: PWM setting frequency
42: Reserve
43: RUN_EN (the digital input terminal running enable)
44: PID_OFF (the digital input terminal stopping PID enable)
45: The second mode
46: Initial curling radius selection terminal 1
47: Initial curling radius selection terminal 2
48: Thickness selection terminal 1
49: Thickness selection terminal 2
50: Wind-up roll-down switching
51: Predrive reference
52: Torque memory
53: Torque memory enable
54: Turn counting signal (note1)
55: Switch speed/Torque control
56: Curling radius restore
57: High-speed pulse input function (note1)
58: Analog terminal AI1 priority
59: Analog terminal AI2 priority
60: Starting/Stopping of PLC
61: Origin retry enable function SHOM
62: Origin retry setting origin ORGP
63: Switch position/Speed control
64: External switch zero-servo
65: External accelerate/decelerate pause
66: External forced stop
67: coil diameter calculation Stop
68: Single point positioning can make
69: Multipoint positioning can make
70: entire position control pulse input command can make
71: External torque command polarity reverse
99999: Not choose in addition of terminal function
03-01
P.84
DI2 function selection Same as 03-00
1