GT610/GT620 Series High Performance Servo Driver User Manual
- 63 -
and users do not need to change.
F0-19
JOG key
function
selection
0: Jog control
1: Reverse control
1
0
○
This parameter is for
JOG
function key selection. When this parameter is set to 0,
JOG
function key is a jogging operation; when set to 1,
JOG
function key is a
reversal operation.
F0-20
Power-off
deceleration
stop start
0: Not to start
1: Start
1
0
○
F0-21
Power-off
deceleration
stop time
0
~
360.00S
0.01S
1.00S
○
When F0-20 is set to 0, power-off deceleration stop will not start, and stop will be
carried out freely after power failure;
When F0-20 is set to 1, power-off deceleration stop will start, and deceleration
stop will be carried out according to power-off deceleration stop time after power
failure. Power-off deceleration stop time is set by F0-21.
F0-22
Over voltage stall
detection level
110
~
150
%
1
%
131
%
×
This parameter defines over voltage stall over-voltage point, and over-voltage
stalling protection function means to compare bus voltage detected during driver
deceleration operation with stall detection over-voltage point, if it surpasses stall
over-voltage point, driver output rotation speed will stop decreasing, after bus
voltage is detected to be lower than stall over-voltage point again, implement
deceleration operation, as shown in the following figure.