DYNISCO UPR800 Series Instruction Manual
Page | 9
•
Electrostatic discharge (according to EN 61000-4-2):
contact discharge = 4kV; air discharge = 8kV
•
Radio-frequency electrical magnetic (according to EN 61000-4-3):
EM field (amplit. mod.) = 10 V/m (80 MHz to 1 GHz);
3V/m (1,4 GHz to 2 GHz);
1 V/m (2 GHz to 2,7 GHz)
•
Electrical fast transient/burst (according to EN 61000-4-4):
AC Power = 2kV;
I/O Signal/Control = 2kV (5/50 ns, 5 kHz);
I/O Signal/Control connected directly to mains supply = 2kV (5/50 ns,
5 kHz)
•
Surge (according to EN 61000-4-5):
AC power = 1kV (Line to Line) / 2kV (Line to GND);
I/O Signal/Control (analog inputs excluded) = 1kV (Line to Line) / 2kV
(Line to GND)
•
Radio frequency common mode (according to EN 61000-4-6):
AC Power = 3 V (150kHz to 80 MHz);
I/O Signal/Control = 3 V (150kHz to 80 MHz)
•
Voltage dips/short interruptions (according to EN 61000-4-11):
0% during 1 cycle; 40% during 12 cycles; 70% during 30 cycles
This equipment is intended for use in an industrial location. There may be potential
difficulties ensuring electromagnetic compatibility in other environmental due to conducted
as well as radiated disturbances.
Safety Requirements:
The instrument is compliant with the European Directive 2006/95/CE according to
Reference Standard EN 61010-1 for installation category I and pollution degree 2
Installation category CAT I:
Voltage transients on any power connected to the
instrument must not exceed 1.5kV.
Pollution degree 2:
Conductive pollution must be excluded from the
cabinet in which the instrument is mounted.
2.3 Display Specifications
Display:
LED technology, custom type.
Upper Digits:
Red color, 5 numeric digits, 7 segments with decimal point 13.2mm high.
Lower Digits:
Green color, 5 alphanumeric digits (British flag), 14 segments with decimal
points. 11.3mm high.
Bar Graph:
Red color, 35 segment with 3% resolution. Displays continuous bar graph to
indicate the measured variable of the primary input (0-100% full scale). Alarm set point
values displayed. Last segment blinks for pressure greater than full scale value.