DYNISCO UPR800 Series Instruction Manual
Page | 8
2.0 SPECIFICATIONS
2.1 Mechanical Specifications
Case:
Polycarbonate Black color Self-extinguishing degree VO according to UL 94
Front Panel:
Designed and verified for IP65 and NEMA 4X for indoor location
Installation:
Panel mounting
Rear Terminal Block:
43 screw terminals with rear safety cover
2.2 Main Power Supply & Environmental Specification
Main Power Supply:
From 100 to 240Vac (-15% to 10%), 50/60 Hz switching. Option:
24Vac/dc
Power supply variation:
From -15% to 10% (for 100 to 240Vac). From 14 to 32 Vdc or
from 14 to 30 Vac (for optional 24Vac/dc).
Power Consumption:
15VA, max.
Insulation Resistance:
100 M
N
@500Vdc
Dielectric Strength:
1500V rms for 1 min, 1800V for 1 sec
Ambient Temperature:
From 0 to 50°C
Storage Temperature:
From -20 to 70°C
Humidity:
Max 85% RH non-condensing
Watchdog:
Hw/Sw is provided for automatic restart
Agency Approvals:
UL File # 193253
Self-Certification:
CE
Electromagnetic Compatibility and Safety Requirements:
The instrument is CE
Marked. It is compliant with the European Directive 2004/108/CE according to Product
Standard EN 61326-1.
Emission limit:
class A – group 1 ISM for equipment suitable for use in all
establishments other then domestic and those directly connected to a
low voltage power supply network which supplies buildings used for
domestic purposes.
Immunity: