6.1 Terminal Assignments
T
er
m
in
al
Terminal
Assignment -
Description
Function
category / class
Voltage
Rating,
V
Current
Rating,
A
Load type and Rating
1
RTD, T/C +
Secondary Inputs
CAT I
2 Vdc 0.001
Adc
3
RTD, T/C -, mA/V -
4
mA +, RTD compensation
0.020 Adc
5
V +
10 Vdc
6
SIG +
Secondary Input Strain
Gage
CAT I
From 340
N
to 5000
N
,
Excitation 10Vdc ±7% (between
EXC + and EXC -)
7
SIG -
8
CAL2
10 EXC
+
11
EXC - , CAL1
12 SIG
+
Main Input Strain Gage
CAT I
From 340
N
to 5000
N
,
Excitation 10Vdc ±7% (between
EXC + and EXC -)
13 SIG
-
14 CAL2
16 EXC
+
17
EXC - , CAL1, mA -, V -
18 mA
+
Main Linear Inputs
CAT I
0.020
Adc
19
V +
10 Vdc
21 OUT1
mA/V
+
Main Analog
Retransmission
Class 2
±12.5 Vdc min load 5K
N
.
-5/+25 mA max load 500
N
(max. load 400
K
over 20 mA).
22 OUT1
mA/V
-
23
RESET
Remote Reset of Alarm
and/or peak
Class 2
Dry Contact switch
(voltage free)
24
29 SHIELD
Standard ProfiBus
Communication
Class 2
30 5VP
31 B/B’
32 A/A’
33 DGND
45 ALARM1
N.O.
Relay contacts used to
identify an event (alarm)
condition
240 Vac, 2A , resistive
46 ALARM1
C
47 ALARM1
N.C
48 ALARM2
N.O.
49 ALARM2
C
50 ALARM2
N.C.
51 ALARM3
C
52 ALARM3
N.C./N.O.
53
Line
~ or +
Main Power Supply
(according to the Product Code)
100 – 240Vac
27VA maximum
or
24Vdc, 12W maximum
24Vac, 18VA maximum
Class 2
54
Neutral
~ or -
55 Earth
(Ground)
56 OUT2
mA/V
+
Secondary Analog
Retransmission
Class 2
±12.5Vdc min load 5K
N
.
-5/+25 mA max load 500
N
(max. load 400
K
over 20 mA).
57 OUT2
mA/V
-
58 Vdc
SUPPLY
+
Auxiliary Power Supply
Class 2
24 Vdc
0.063 Adc
(1.5W)
59 Vdc
SUPPLY
-
60 A/A’
Serial Communication
RS485
Class 2
61 B/B’
62 C
Note:
The instrument is not suitable for use with equipment for measurement within measurement categories II, III and IV.