Noise level gas, dual fuel and oil burner Monobloc
dreizler A 3001 E - 18.12.2015 | A 2016 - 1.09 | EN - 01.05.2009
133
41 Noise level gas, dual fuel and oil burner Monobloc
41.1 Noise emissions in series marathon
®
gas burner Monobloc
CAUTION!
Service and operating personnel must wear hearing protection, when carrying out
maintenance, service and operational tasks at noise levels above 80dB(A).
Tab. 41-1 All values measured during individual operation
Tab. 41-2 All values measured during individual operation
Gas burner
M..., M...ARZ
Noise level
dB(A)
without noise dam
cap
Noise level
dB(A)
with serial noise dam
cap
L1 to L4 (HT)
Noise level
dB(A)
with optional
noise dam cap
SH 20
Measuring point 1
Measuring point 1
Measuring point 1
M 121
70
62
59
M 201
70
65
59
M 301
75
68
59
M 601.1
75
72
63
M 601
85
76
67
M 1001
85
75
66
M 1501
85
78
69
M 2001
85
78
69
M 3001
85
78
69
M 5001.1
85
78
69
with hood SH 15
M 5001
88
79
77
Gas burner
M..., M...ARZ
Noise level
dB(A)
without
noise dam cap
Noise level
dB(A)
with optional
noise dam cap
SH 20
Measuring point 1
Measuring point 1
M 5001.4 VM 18.5
---
90
77
M 5001.4 VM 22
---
90
77
M 10001.1 VM 22
---
90
77
M 10001.2 VM 30
---
90
77
M 10001.3 VM 30
---
90
77
M 10001.4 VM 45
---
90
77
M 10001.4 VM 55
---
90
77