Summary of Contents for ALT30

Page 1: ...ALTURI MANUAL MADE IN USA 20 026 ...

Page 2: ......

Page 3: ... 455 28 457 10 025 21 269 24 381 25 123 1 000 10 025 23 622 28 067 25 455 46 725 36 000 4 475 6 250 1 085 803 10 986 25 409 27 972 36 000 34 457 10 025 21 269 24 381 25 123 1 000 10 025 23 622 28 067 25 455 52 725 42 000 4 475 6 250 1 085 803 10 986 25 418 27 972 42 000 40 457 10 025 LINE DRAWINGS ALT30 ALT36 ALT42 ...

Page 4: ...vice Welcome to the Summerset family and we hope you love your new grill Please record the following information and refer to it when contacting Summerset Professional Grills or an authorized dealer The serial number is located on the rating plate The rating plate is located on the exterior basin of the grill fire box and on the underneath side of the drip tray select models only Serial Number Mod...

Page 5: ...anual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 5 psi 3 5kPa WARNING Improper installation adjustment alteration service or maintenance can cause property damage injury or death Read this manual thoroughly before installation use or servicing of this product THIS PRODUCT IS DESIGNED FOR OUTDOOR USE ONLY WARNING CODE AND SUPPLY...

Page 6: ...supply cord and the fuel supply hose away from any heated surfaces Electrical cords should be placed away from walkways to avoid tripping hazard Do not repair or replace any part of the grill unless specifically recommended in this manual Other service should be performed by a qualified technician If the grill is installed by a professional installer or technician be sure that he she shows you whe...

Page 7: ......

Page 8: ...TABLE OF CONTENTS Replacement Parts List Exploded View Before Grilling Installation Gas Requirements Lighting The Grill Maintenance Tips Grill Features Warranty 1 2 3 4 6 9 9 11 12 ...

Page 9: ...Switch Swtch Light SS 1 Swtch Light SS 1 Swtch Light SS 1 24 Front Panel Front Alt30 1 Front Alt36 1 Front Alt42 1 25 Knob Bezel Knob Bezel LG 4 Knob Bezel LG 4 Knob Bezel LG 5 26 Knob Knob LG 4 Knob LG 4 Knob LG 5 27 Alturi Logo Plate Logo Plate Alt 1 Logo Plate Alt 1 Logo Plate Alt 1 28 Smoker Tray 2018 Older 1 2018 Older 0 2018 Older 1 29 A LED Harness old style LED Harn Alt30 1 LED Harn Alt36 ...

Page 10: ...2 EXPLODED VIEW ...

Page 11: ...ing added This drop in pressure affects grill performance PROPER LEVELING PROPER LEVELING DURING INSTALLATION IS CRITICAL A GRILL THAT IS OUT OF LEVEL WILL CAUSE ERRATIC BURNER COMBUSTION AND INEFFICIENT UNEVEN HEATING THE GRILL SHOULD BE LEVEL IN ALL DIRECTIONS ADJUSTMENTS MAY NEED TO BE MADE EACH TIME WHEN MOVING A FREESTANDING UNIT CONSTRUCTION ZONES Keep all stainless steel products away from ...

Page 12: ...nt dangerous overheating ALL BBQ ISLANDS MUST BE MANUFACTURED FROM NON COMBUSTIBLE MATERIAL IF COMBUSTIBLE MATERIAL IS BEING USED A SUMMERSET GRILL LINER IS REQUIRED NOTE For the minimum clearances between the grill and any side or rear walls your setup must fall within one or more of the following Clearance between grill and protected combustible wall i e a non combustible wall in front of a comb...

Page 13: ...arance must first be met prior to any non combustible walls beginning behind it OVERHEAD CONSTRUCTION AND EXHAUST HOOD REQUIREMENTS IMPORTANT NOTES DO NOT use this appliance under unprotected combustible overhead construction When installed under overhead non combustible construction an exhaust hood is highly recommended This grill is designed for outdoor use only DO NOT use this grill inside a bu...

Page 14: ... the grill AND with a minimum of 1200 CFM cubic feet per minute for proper outdoor application WARNING GAS LINES Never connect a gas line directly to the grill A pressure regulator must be installed on all gas equipment Removing or failing to install the pressure regulator can result in fire and serious personal injury and will void the warranty MINIMUM PRESSURE REQUIREMENTS Ensure the gas supplie...

Page 15: ...ted in the following manner Use a standard 20 lbs LP tank with QCC 1 fitting Grills set up for LP gas come equipped with an LP hose regulator assembly for connection to a standard 20 lbs LP cylinder Type 1 NOTE DO NOT use any tape pipe dope or threading compound on any flare fitting This will cause a clog in the regulator and prevent your grill from functioning properly Insert the regulator inlet ...

Page 16: ...der must be stored outside in upright position and away from excessive heat CONNECTING TO A SIDE BURNER You will need a T adapter fitting not provided or similar connection to connect a single gas line to both a side burner and a grill We recommend a licensed gas technician install all gas lines See below figure for installation of a T adapter IMPORTANT All installation and all installation parts ...

Page 17: ...e spark ignition After ignition set the knob to the desired setting PLEASE Keep your face and body away from the grill top when lighting 1 If the burner doesn t ignite wait five 5 minutes before repeating steps 4 7 2 DO NOT turn on more than one valve at a time for either MAINTENANCE TIPS PRE HEATING THE GRILL Pre heating your grill every time you use it is extremely important Pre heating allows t...

Page 18: ...nless steel cleaner Solutions used for cleaning concrete and masonry can be very corrosive and will attack stainless steel Be sure your Summerset products are well protected before using these products After each use wipe down the exterior of the grill to remove grease and splatters Use a commercially available stainless steel cleaner to clean and polish the exterior surfaces Doing these things Bu...

Page 19: ...BURNER INSTALLATION The preferred location to install a drop in sear burner is on the far left of the grill This will allow for a sear zone while maximizing the main burner grilling space To install a drop in sear burner Remove the grate and burner covers to access the main burner Remove the cotter pin securing the main burner if necessary Remove main burner Remove cross tube in between main burne...

Page 20: ...etime Warranty on Ice Chests Gold Standard Lifetime Warranty on drains faucets 15 24 REFRIGERATION MODELS 3 year Warranty on all construction including compressors 1 year Warranty on transformer LED bulbs LED harness power source wire LED switches interior halogen light wire bulbs 21 REFRIGERATION MODELS 1 year Warranty on all construction electrical components including compressor transformer LED...

Page 21: ...Summersetgrills com 14520 Delta Lane Suite 105 Huntington Beach CA 92647 800 966 8126 VER 091721 POP ALT MANUAL 2021 ...