22 Ignition transformer
22.1 Ignition transformer ZE 30 / 7.5 (single pole)
22.1.1 Description
The ignition transformer is equipped with a unilaterally earthed high-voltage winding. It functions with single
pole ignition. That means that the ignition electrode ignites against mass. The ignition electrode can me
moved and adjusted on the connection piece of the burner head. It functions as mass against the burner
head.
22.1.2 Technical data
NOTICE:
The best spark gap distance is between 2 and 3mm.
22.1.3 Single-pole ignition
marathon
®
burners up to construction year 2000 are equipped with single-pole ignition.
Fig. 22-1 Electrode gap in single-pole ignition
1
Burner ring
2
Flame tube
3
Ignition electrode
4
Burner plate
Secondary voltage:
7.5 kV
Short-circuit current:
30 mA (60Hz 22 mA)
Power input voltage:
230V / 50Hz
Nominal input voltage:
1.3 A (60Hz 1.0A)
Intermittent operation:
ED 20% (3 minute duty cycle)
High-voltage power supply:
Form C, i.e. insertion spike connection
Radio interference suppression:
a) By way of shielding against electromagnetic and
electrostatic forces.
b) The high-voltage supply line is led separately with-
in the burner.
c) Burner system and ignition transformer are opti-
mally grounded.