Noise level gas, dual fuel and oil burner Monobloc
dreizler A 3001 E - 18.12.2015 | A 2016 - 1.09 | EN - 01.05.2009
134
41.2 Noise levels for series marathon
®
dual fuel and oil burner Monobloc
Tab. 41-3 All values measured during individual operation
Tab. 41-4 All values measured during individual operation
NOTICE:
The noise levels indicated are not guaranteed values. Other results may be measured depending on local
conditions.
NOTICE:
In accordance with Machine Directive 98/37/EC, measurements of noise emissions (EN 15036-2) on heat
generators are carried out by way of a measuring process of accuracy class 2.
Dual fuel burner
MC ...
Noise level
dB(A)
with serial noise insu-
lation hood
L1 to L4 (PROFI)
Noise level
dB(A)
with serial noise dam
cap
L1 to L4 (HT)
Noise level
dB(A)
with optional
noise dam cap
SH 20
Measuring point 1
Measuring point 1
Measuring point 1
MC 301
71
68
59
MC 601
79
76
67
MC 1001
78
75
66
MC 1501
78
75
69
MC 2001
81
78
70
MC 3001
82
79
70
MC 5001.1
82
79
71
with hood SH 15
MC 5001.2
---
80
71
MC 5001.3
---
80
71
Dual fuel burner
MC ...
Oil burner
MC...-L
Noise level
dB(A)
without
noise dam cap
Noise level
dB(A)
with optional
noise dam cap
SH 20
Measuring point 1
Measuring point 1
MC 5001.4 VM 18.5
---
90
77
MC 5001.4 VM 22
---
90
77
MC 10001.1 VM 22
---
90
77
MC 10001.2 VM 30
---
90
77
MC 10001.3 VM 30
---
90
77
MC 10001.4 VM 45
---
90
77
MC 10001.4 VM 55
---
90
77