89
DBC 130II
DBC130II ISE41
3) Shaking of the table
①
Measure
Install the indicator at the end of the spindle
and place the height measuring block
500mm away from the table center in the X
and Z directions before setting the reference
point ("0"). Then, rotate the B axis by each
90
˚ and measure the difference.
▪
Measuring point
: If the table center is set as "0"
From "X500.Z500", rotate the B axis by
each 90
˚ four times to measure 4 points
▪
Tolerance: 0.025mm
②
Correct
The shaking of the table is caused by a
problem with the parallelism between table
bottom and deck. So if you want to correct
the shaking, you should scrape the bottom
or grind the deck as appropriate.
`
15.7 Squareness in division of index table
1) How to measure
(1) Place the square horizontally on the table
deck. While moving the X axis, correct the
parallelism between square and X axis.
▪
To correct the parallelism, use the handle
of a screwdriver to impact on certain points
of the square.
(2) While indexing the B axis, clamp the square
to the table lest that it should move.
(3) While indexing the B axis totally 4 times, one for each 90 degrees, measure the X-
axis parallelism totally 4 times accordingly. The greatest difference is the
measurement.
▪
Measuring point: 0
˚ Position, 90˚ Position, 180˚ Position, 270˚ Position
▪
Tolerance: 0.02mm/500mm
Table
X axis
Summary of Contents for DBC 130 II
Page 1: ...Installation Manual DBC 130Ⅱ Machine Tools ...
Page 2: ......
Page 7: ...5 DBC 130II DBC130II ISE41 Ref 2 Right View Ref 3 Top View ...
Page 9: ...7 DBC 130II DBC130II ISE41 Ref 6 Top view of machine to install semi splash guard on Optional ...
Page 10: ...8 DBC 130II DBC130II ISE41 Ref 7 Top view of machine to install APC on Optional ...
Page 12: ...10 DBC 130II DBC130II ISE41 60 Tool Magazine ...
Page 60: ...58 DBC 130II DBC130II ISE41 Z axis ...
Page 121: ...119 DBC 130II DBC130II ISE41 19 Installation Complete ...