![Dinamica Generale DG8000 Operator'S Manual Download Page 99](http://html1.mh-extra.com/html/dinamica-generale/dg8000/dg8000_operators-manual_2505533099.webp)
Service
INDICATOR DG8000 RevB0
E
N
GL
IS
H
97
PROCEDURE 4
Ref. NO / NO
Check the functioning of the SYSTEM and of the SENSORS
S
WITCH OFF THE MICROCOMPUTER
.
t) Just leave one sensor
connected to the scale.
u) Switch on the microcomputer.
v) Do the TARE (use the microcomputer’s manuals for instructions).
w) The scale has to be stable, displaying “0” Kg.
x) Check the correct functioning trying to load weight on the connected sensor (the displayed weight
is not important, but it must be steady).
REPEAT THE TEST CONNECTING EACH SENSOR, ONE AT A TIME, IN THE ORIGINAL CONNECTOR .
RESULT
CAUSE
ACTION
Zero and weight of a sensor
NON
stable.
The sensor is damaged
Contact the assistance service
Zero and weight of all the
sensors on the same connector
NOT
stable
The microcomputer is
damaged
Contact the assistance service
Zero and weight stable with all
the sensors in the same
connector
None
Repeat the test with another
scale connector.
Zero and weight stable with all
the sensors in all the
connectors
The system works correctly.
Connect everything and try again
in normal use