![Dinamica Generale DG8000 Operator'S Manual Download Page 44](http://html1.mh-extra.com/html/dinamica-generale/dg8000/dg8000_operators-manual_2505533044.webp)
Configuration
INDICATOR DG8000 RevB0
42
Password 603 – How to Enable the XL Display
1
Selection of the communication
protocol with the display accessories:
Normal
(to communicate with
Weight Repeater),
Advanced
(to communicate with XL
Display),
Full
(to communicate with
Weight Repeater and XL Display)
Select the desired mode with the
↑ or ↓
keys and confirm the selection with the
Enter key
Password 1066 – User and Password Activation
The DG8000 gives you the possibility to have a different access to all functions in order to
trace the loading /unloading operations made by a specific user.
This function has to be enabled/disabled specifically by the user following these easy
steps:
1
Once entered the password, “
User
and Password Activation”
will appear
on the screen, select
Yes
by using the
cursor and afterwards
Enter
to
confirm.
2
Regarding the “
Active User list Auto update”
item:
a)
Select
Yes
, if you prefer that the operators list is
UPDATED
with all the new
operators present in the memory card
b)
Select
No
, if you prefer that the operators list is
NOT UPDATED
with all the new
operators present in the memory card.
The DG8000 gives you the possibility to
enable/ disable
the function “
Operators
Management
”. The creation of the OPERATORS is possible only by DTM software.