Configuration
INDICATOR DG8000 RevB0
31
E
N
GL
IS
H
Auto Next Mode = Percent
In order to work properly with this mode you must appropriately set the parameters Auto
Next Threshold % and Auto Next Timer. The parameter Alarm Threshold% and the
Tolerance (Weight) on the DTM are ignored, while Alarm Delay and Stabilization Time are
managed. Using this mode when you load a weight equal to
Target – [(Auto Next Threshold %) * Target / 100)]
It activates the siren intermittently, and starts a countdown equal to Auto Next Timer , at
the end of this timer even if you have not reached the Target Weight (and also after an
acoustic alarm fixed to (Alarm Delay ) and eventually to a Stabilization Time (if the
Stabilization Time is set) ), the DG8000 automatically switches to the next Component.
Tolerance (Weight)
The field Tolerance (Weight), can be set only on DTM; it is used only in relation to the
parameter Auto Next Mode = Weight, otherwise it is ignored. (see information above)