![Dinamica Generale DG8000 Operator'S Manual Download Page 92](http://html1.mh-extra.com/html/dinamica-generale/dg8000/dg8000_operators-manual_2505533092.webp)
Service
INDICATOR DG8000 RevB0
90
OVERRANGE ALARM
DISPLAY
CAUSE
SOLUTION
DG400
DG500
DG600
DG8000
Cause1
The microcomputer can not read the
signal of the load cells: the load cell
connection cable does not work
correctly.
Cause2
A connection cable or a load cell does
not work correctly.
Cause3
The signal coming from the sensors is
out of the valid “RANGE” (see the
password 99).
Solution1
:
do the TARE.
Solution2
:
do the calibration with password
12 and then do the TARE.
Solution3
:
do the check described as follows.
LOW BATTERY ALARM
DISPLAY
CAUSE
SOLUTION
DG400
DG500
DG600
DG8000
The microcomputer power is lower
than the fixed value.
Solution1
:
check the efficiency of the
battery.
Solution2
:
check the CABLES that supply
the power from the BATTERY to
the MICROCOMPUTER.
UNSTABLE WEIGHT
DISPLAY
CAUSE
SOLUTION
The weight continues to
oscillate between tens
or hundreds kg
The signal coming from the sensors
is jammed: a cable or a load cell does
not work correctly.
Do the check described as
follows.