Programming Parameters for DSSI Devices
VAX 4000 Model 108 User Information E-9
PARAMS>SHOW NODENAME
Parameter Current Default Type Radix
--------- ---------------- ---------------- -------- -----
NODENAME SYSDSK RF73 String Ascii B
Setting the System ID
__________________________NOTE ____________________________
This parameter is modified only when replacing a device. Only Digital service
representatives and licensed self-maintenance customers should remove devices. All
parameters for the replacement device should be programmed to match those of the
original device.
____________________________________________________________
After entering the DUP driver utility for a specified device, you can examine and set the
system ID for the device as follows.
1. At
the
PARAMS>
prompt, enter
SHOW SYSTEMID
to check the system ID of the
device to which you are currently connected.
2. Enter
SET SYSTEMID
System ID
(enter the desired serial number-based system
ID).
3. Enter
SHOW SYSTEMID
to verify the new system ID.
This shows the steps for changing the system ID of a specified device from the factory-
supplied ID to 1402193310841 (the system ID for the replacement device is programmed
to match that of the original).
PARAMS>SHOW SYSTEMID
Parameter Current Default Type Radix
--------- ---------------- ---------------- -------- -----
SYSTEMID 0402193310841 0000000000000 Quadword Hex B
PARAMS>SET SYSTEMID 1402193310841
PARAMS>SHOW SYSTEMID