Diagnostic Tests and Commands
VAX 4000 Model 108 User Information 6–15
DHW41/2 V1.6
>>>
Test Utility Number Column
Device Mnemonic Column
Device Status Column
SCSI IDs and SCSI Device Names
The test numbers listed identify the normal test or script number to run to verify the device
listed. There are additional tests and utilities for some devices. Test 0 calls the power-up
script.
__________________________NOTE ____________________________
The lines for F0, E8 and EC display only if the applicable option is present.
____________________________________________________________
If the system detects errors in the most recent power-up tests and diagnostic utilities, it
responds with a configuration display similar to the following:
KA57-A V1.0, VMB 2.16
08-00-2B-2B-16-91
64MB
TstNbr DevNam Info
------ -------- --------------------------
0 CPU_BD OK
A8 MEMORY OK
E4 DZ ?? 001 0048
E0 SCSI OK
3-RZ28D 4 RRD45 6-Adapter
5F NI OK