Diagnostic Tests and Commands
VAX 4000 Model 108 User Information 6–7
_____________________________NOTE ____________________________
Tests 101 through 107 are reserved for use by Digital services.
_______________________________________________________________
The tests and utilities shown in the following table are for option cards, which may or may
not be present, depending upon the options you ordered.
Table 6-1 Option Card Tests
Test
Name
Usage
E8
SYNC
Synchronous COMM option card (DSW41/42/43)
E9
SYNC_Utility
Synchronous COMM option card (DSW41/42/43)
EC
ASYNC
Asynchronous option card (DHW41/42)
F0
SCSI_option
SCSI option card for 2nd SCSI bus B (KZDDA)
F1
SCSI_Opt_Utility
SCSI option card for 2nd SCSI bus B (KZDDA)
F2
SCSI_MAP_Option
SCSI option card for 2nd SCSI bus B (KZDDA)
To run the diagnostic tests, enter either
TEST
or
T
followed by the test number.
You can specify optional parameters for some tests, but you would not do so normally. If
you decide to specify optional parameters, then the following conditions apply:
•
Each test uses up to 10 parameters, no more than 7 may be inputted on a command
line.
Most of these parameters are assigned values automatically by the system. These
parameters are indicated by an asterisk (*) in the parameters column of (t9e).
•
If a parameter can be assigned a value, the name of the parameter is shown in the
parameters column in (t9e).
You can use test 9E with the test number as a parameter to show a list of legal
parameters and valid values for the test number. For example, enter
T 9E 30
to
show a list of legal parameters and valid values for test number 30
(Memory_Init_Bitmap).
•
There is a dependency between some tests.
•
Failures can occur if dependencies between tests are not followed.