Diagnostic Tests and Commands
VAX 4000 Model 108 User Information 6–11
Performing normal system tests.
74..73..72..71..70..69..68..67..66..65..64..63..62..61..60..59..
58..57..56..55..54..53..52..51..50..49..48..47..46..45..44..43..
42..41..40..39..38..37..36..35..34..33..32..31..30..29..28..27..
26..25..24..23..22..
? Test_Subtest_40_06 Loop_Subtest=00 Err_Type=FF DE_Memory_count_pages.lis
21..20..19..18..17..16..15..14..13..12..11..10..09..08..07..06..
05..04..03..
Memory Set 0: 00000000 to 07FFFFF, 128MBs, 0 good pages, 262144 bad pages
Set 0 on SIMM_carrier_J4 (J5...) (J6...) (J7 ??)
(J8...)
Memory Set 1: 08000000 to 07FFFFFF, 128MBs, 262144 good pages, 0 bad pages
Set 1 on SIMM_carrier_J4 (J1...) (J2...) (J3...) (J4...)
Total of 256MBs, 393216 good pages, 0 bad pages, 7 reserved pages
Normal Operation not possible.
Indicates the SIMM in J7 is defective.
Example 4
The following example represents a case where all SIMMs of a set are missing or
incorrectly installed. There is no usable memory for testing to run to completion. All the
SIMMs are missing here.
KA57-A V1.0, VMB 2.16
Performing normal system tests.
71..70..69..68..67..66..65..64..63..62..61..60..59..58..57..56..55..54..53..