Diagnostic Tests and Commands
6–10 VAX 4000 Model 108 User Information
Performing normal system tests.
71..70..69..68..67..66..65..64..63..62..61..60..59..58..57..56..
55..54..53..52..51..50..49..48..47..46..45..44..43..42..41..40..
39..38..37..36..35..34..33..32..31..
Memory configuration error.
? Test_Subtest_40_09 Loop_Subtest=00 Err_Type=FF
DE_Memory_count_pages.lis
30..29..28..27..26..25..24..23..22..21..20..19..18..17..16..15..
14..13..12..11..10..09..08..07..06..05..04..03..
Memory Set 0: 00000000 to 03FFFFFF, 64MBs, 131072 good pages, 0 bad pages
Set 0 on SIMM_carrier_J4 (J5...) (J6...) (J7...) (J8 ??)
Memory Set 1: 00000000 to 07FFFFFF, 128MBs, 262144 good pages, 0 bad pages
Set 1 on SIMM_carrier_J4 (J1...) (J2...) (J3...) (J4...)
Total of 192MBs, 393216 good pages, 0 bad pages, 7 reserved pages
Tests completed.
>>>
Indicates no memory SIMM installed here or SIMM not correctly installed.
Example 3
The following example represents a case where the SIMM installed in J7 of the carrier
installed in J4 of the CPU is bad. In this example SIMM J7 is defective.
KA57-A V1.0, VMB 2.16