Diagnostic Tests and Commands
6–14 VAX 4000 Model 108 User Information
The SIMM on J7 of the SIMM carrier installed in J1 of the CPU is defective or not
installed.
Configuration Display
The configuration display shows the system configuration and the error messages that were
detected while the most recent power-up tests, diagnostic tests, and utilities were running.
If you add expansion boxes to the system and do not run the power-up tests or appropriate
diagnostic test or utility, the configuration display does not recognize the reconfiguration.
Enter the following command to see the configuration display:
>>> Show CONFIG
If the system does not detect any errors in the most recent power-up tests or diagnostic
utilities, it responds with a configuration display similar to the following:
KA57-A V1.0, VMB 2.16
08-00-2B-2B-16-91
64MB
TstNbr DevNam Info
------ -------- --------------------------
0 CPU_BD OK
A8 MEM OK
E4 DZ OK
E0 SCSI OK
3-RZ28D 4-RRD45 6-Adapter
5F NI OK
5C DSSI OK
0 QBUS OK
E8 COMM OK
DSW41/42 2 CHANNEL V3.11-47
EC ASYNC OK