Connecting to a Network
Verify Your ThinWire Ethernet Network Installation
To verify the ThinWire Ethernet installation, you need to be correctly
connected to a ThinWire Ethernet network or you need the ThinWire
Ethernet terminator attached to your system unit. You also need a console
terminal.
1. Turn on your server system. A power-up display similar to the
following appears:
F_..E...D...C...B...A...9...8...7...6...5...4...3...2_..1
2. The console prompt
>>>
also appears. If the console prompt does not
appear, press the halt button on the back of the system unit.
Halt Button
MLO-002754
M A - 0 3 6 2 - 9 0 . D G
3. Enter the following command:
>>> TEST 50
Return
The system responds with another display. If the last line of the
display is NI 0100.0001, then the Ethernet subsystem is working.
If a number between 0100.0002 and 0100.7000 appears on that line of
the display, there is a failure in the Ethernet subsystem.
If NI 0100.7000 or any number above 0100.7000 appears on this line,
check all Ethernet connections.