OPERATOR’S MANUAL
IntelliAg MVT
11001-1643A-201411
46 / MATERIAL SETUP
MAXIMUM RATE
Maximum Rate establishes the maximum application rate in pounds per
acre (kg/Ha) that the control allows. Target Rate cannot be incremented to a
value greater than this established maximum rate.
MINIMUM RATE
Minimum Rate establishes the minimum application rate in pounds per acre
(kg/Ha) that the control allows. Target Rate cannot be decremented to a
value lower than this established minimum rate.
INCREASE/DECREASE %
The increment and decrement percent rate establishes the percentage of
change of the entered target rate applied each time the Increment/
Decrement button is pressed on the Main Work Screen.
IMPORTANT: The maximum or minimum rates may not be reached if
the % increase or decrease, based off the target rate,
exceeds the maximum or minimum rate limits set.
EXAMPLE: Maximum Rate is set for 101. Target Rate is set for 100. If the %
increase is set at 2%, the maximum rate of 101 will not be met because the
% increase of 2% would exceed the 101 maximum rate limit.
Figure 44
Granular Control Material Type Screen 2
DENSITY
Density is the weight per volume of material to be dispensed and is required
to convert the spreader constant. If density is unknown, a value of 1 can be
entered to perform a spreader constant. This will place the channel into a
pure pulse/ft
3
granular system.
Nitro Software, Inc.
100 Portable Document Lane
Wonderland
Page 51