OPERATOR’S MANUAL
IntelliAg MVT
11001-1643A-201411
CUSTOMIZING THE WORK SCREEN / 111
SINGULATION ROW SCAN
Singulation Row Scan displays the percent singulation of each of the
planter’s rows. The displayed row increments every four seconds. After the
last row is displayed, the scan will re-sequence beginning with the first
active row.
SINGULATION MIN MAX SCAN
Singulation Min Max Scan alternates the display of the minimum row
singulation and maximum row singulation every two seconds. When a
minimum row displays, the corresponding symbol is shown with the row
number.
GROUND SPEED
Ground Speed displays the current ground speed of the tractor in miles per
hour (Kph). The ground speed source is defined during the Ground Speed
Calibration setup.
This data item also displays the implement status using an up/down arrow
next to the tractor icon.
TOTAL AREA
NOTE:
Data Items on the Main Work
screen with a check box allows
the number to be reset to zero.
Total Area displays the area covered by the implement in acres (Ha). Total
area is calculated using the Implement Width parameter entered on the
Row Setup screen. Area accumulates for seeding when seeds are
detected on at least one seeding row and the ground speed is above the
shutoff speed parameter entered on the Ground Speed Calibration
screen. This accumulator is independent of any other area accumulator and
can be reset to 0.0 at any time. Current area is retained after power down. If
no rows are configured, the Total Area Accumulator will use the largest
channel width.