OPERATOR’S MANUAL
IntelliAg MVT
11001-1643A-201411
40 / MATERIAL SETUP
DEFINE MATERIAL PARAMETERS
After creating a material name that appears at the top of the Material
Configuration screen, material parameters are entered that include:
•
Type
•
Units
•
Preset Method
•
Seeds per Revolution
•
Disc Low/High Limits
•
Alarms
•
On/Off Pattern
To Define Material Parameters:
1. At the Materials screen, use the rotary button to highlight each yellow
input box.
2. Push in the rotary button to select or change the value.
3. Press the More button to add additional parameters.
Figure 38
Planter Control Setup Screen - Preset Method Disabled
TYPE
Type establishes the desired type of application control channel used for a
specific material. This step is very important. Material type must
correctly match Control type.
NOTE:
Refer to the Operate section for
Monitor Only setup and operate
instructions.
* Monitor Only is typically used for ground drive applications to monitor
population with high and low alarms. All seeding control channels MUST
be disabled in this configuration and/or no rows assigned to those
seeding channels.
Type
Used for
Planter Control
seeding on a row crop planter
* Monitor Only
population monitoring only
Liquid Control
liquid application control
Granular Control
granular application control for drills and planters
Nitro Software, Inc.
100 Portable Document Lane
Wonderland
Page 45