OPERATOR’S MANUAL
IntelliAg MVT
11001-1643A-201411
MATERIAL SETUP / 43
TARGET RATE
The desired rate of application displays in KS (thousand) seeds per acre or
(KS/Ha).
MAXIMUM RATE
The maximum application rate in KS (thousand) seeds per acre or (KS/Ha)
that the control allows. Target rate cannot be incremented to a value greater
than this established maximum rate.
MINIMUM RATE
The minimum application rate in KS (thousand) seeds per acre or (KS/Ha)
that the control allows. Target Rate cannot be decremented to a value lower
than this established minimum rate.
INCREASE/DECREASE %
Establishes the percentage of change of the entered target rate that is
applied each time the Material Increment/Decrement button is pressed on
the Main Work Screen.
IMPORTANT: The Maximum or Minimum Rates may not be reached if
the % increase or decrease, based off the Target Rate,
exceeds the maximum or minimum rate limits set.
EXAMPLE: Maximum Rate is set for 101. Target Rate is set for 100. If the
% increase is set at 2%, the maximum rate of 101 will not be met because
the % increase of 2% would exceed the 101 maximum rate limit.
NOTE:
Press the More button on the
Materials screen to view
second screen.
SEEDS PER REV
Displays the number of seeds that are dropped in one revolution of the seed
disk.
Figure 42
Material Setup (Second Screen)
DISC HIGH/LOW LIMITS
The maximum or minimum RPM at which the seed disc will operate. The
control will not allow the seed disc to rotate faster than the Disc High or Low
Limit setting.
Nitro Software, Inc.
100 Portable Document Lane
Wonderland
Page 48