OPERATOR’S MANUAL
IntelliAg MVT
11001-1643A-201411
GROUND SPEED SETUP / 95
Figure 76
Minimum Override
MASTER SWITCH TIMEOUT
Master Switch Timeout determines the length of time before the system
disables the operate function after ground speed is 0 (zero) if the master/
control switch remains in the ON position. After the delay time elapses, an
alarm is issued stating that the master/control switch must be toggled OFF/
ON before the system will restart.
GROUND FAIL ALARM DELAY
Alarm Delay determines the length of time after the ground speed goes to
zero and seed flow continues before the alarm sounds. This alarm only
applies when all control channels are disabled and the system is running in
a Planter Monitor Only mode.
IMPLEMENT LIFT
If an implement lift switch is used, the implement lift status must be enabled.
While operating, an alarm condition will occur if the master/control switch is
off for more than 5 to 10 seconds, the implement is down, and ground
speed is greater than zero. An Alarm Cancel button allows the alarm to be
deactivated during the current power cycle. If an implement lift switch is not
required, this function should be disabled.
A minimum override of
5 mph entered at Speed
Set screen. When enabled,
speed displays in black box
and cannot be adjusted.