OPERATOR’S MANUAL
IntelliAg MVT
11001-1643A-201411
MATERIAL SETUP / 47
SPREADER CONSTANT
Spreader Constant establishes the value for the amount of material per
pulse of the application rate sensor. The value entered defines the pulses
from the feedback sensor per ft
3
of material discharged. Each material (and
gate setting as applicable) has its own spreader constant. For best results,
the value must be as accurate as possible. This value may be set
manually, however, using the spreader constant calibration is
recommended for the most accurate results.
LOW/HIGH SHAFT RPM
Low/High Shaft RPM establishes the low shaft and high shaft RPM the
meter shaft will operate. Low shaft RPM is the lowest shaft RPM speed that
the control channel will operate. High shaft RPM is the highest shaft RPM
the control channel will operate.
PRODUCT LEVEL ALARM
The product level alarm sets the weight (lbs/Kg) to alert of low seed levels.
The entered value is an estimate in lbs.
LIQUID FLOW MATERIAL TYPE
Material setup for liquid flow control of fertilizer applications.
Figure 45
Liquid Flow Material Type
TYPE
Select Liquid Flow Control as the control type.
PRESET METHOD ENABLED
The Preset Method table allows 10 user-defined target rates to be entered.
When enabled, target rates can be adjusted from the Main Work screen
using the Increment/Decrement buttons (
Nitro Software, Inc.
100 Portable Document Lane
Wonderland
Page 52