OPERATOR’S MANUAL
IntelliAg MVT
11001-1643A-201411
SECTION CONTROL -MANUAL / 99
ASSIGN SHUTOFF SWITCHES
The Clutch Set screen identifies what switches on the row shutoff switch
box enable and disable planter sections or outputs.
Control channels can be linked to RSM switches and outputs. When linked
and a switch is shutoff, the corresponding width (number of rows x row
spacing assigned to that switch) is reduced on the channel the switches are
linked.
For example, if output 1 and switch 1 are assigned to 2 rows at 3” spacing
and that switch is shutoff, the width of channel 2 is reduced by 60”. The
assumption is made that 60” of channel 2 is no longer applying material so
the application rate adjustment for active width applying material is
maintained and the acre counter is correct.
To Assign Switches to Outputs:
1. Press the Clutch Set button.
2. Enter the switch number that controls the on/off status of each module
output.
3. Press the Link Channel input box to link a channel to a switch
(checkmark).
Figure 80
Assign Shutoff Switches Screen