DDEC VI ELECTRONIC CONTROLS APPLICATION AND INSTALLATION
Diagnostic
Name
Parameter
Group
Min
Max
Default
Access
Range
4 06 DO Fault
Detection
35
0
1
0
DRS, VEPS
0=disabled, 1=enabled
4 06 DO
Selection
35
0
3
1
DRS, VEPS
0=disabled, 1=grid heater lamp,
2=accelerator pedal idle position, 3=run
signal / starter lockout
4 07 DO Fault
Detection
35
0
1
0
DRS, VEPS
0=disabled, 1=enabled
4 07 DO
Selection
35
0
13
13
DRS, VEPS
0=disabled, 1=accelerator pedal
kick down, 2=actual torque, 3=road
speed, 4=engine speed, 5=coolant
temperature, 6=pedal torque, 7=boost
temperature, 8=oil pressure (PLD
threshold), 9=coolant temperature (PLD
threshold), 10=vehicle power shutdown
/ ignition relay, 11=optimized idle ACC
bus (ignition relay), 12=split valve 1,
13=High Exhaust Temperature Lamp
4 08 DI
Selection
13
0
2
1
DRS, VEPS
0=disable, 1=clutch switch, 2=PTO
request for AGS2
4 09 DO Fault
Detection
35
0
1
0
DRS, VEPS
0=disabled, 1=enabled
4 09 DO
Selection
35
0
12
0
DRS, VEPS
0=disabled, 1=accelerator pedal idle
position, 2=actual torque, 3=road
speed, 4=engine speed, 5=coolant
temperature, 6=pedal torque, 7=boost
temperature, 8=oil pressure (PLD
threshold), 9=coolant temperature (PLD
threshold), 10=optimized idle active
lamp, 11=deceleration lamp, 12=Fuso
ground starter lockout relay
4 10 DO Fault
Detection
35
0
1
0
DRS, VEPS
0=disabled, 1=enabled
4 10 DO
Selection
35
0
3
0
DRS, VEPS
0=disabled, 1=not used, 2=not used,
3=vehicle power shutdown / ignition
relay
4 12 PWM
Output
Selection
9
0
10
0
DRS, VEPS
0=disabled, 1=throttle torque 10%..90%,
2=difference torque, 3=throttle torque
90%..10%, 4=actual torque, 5=load
torque (no idle torque for automatic
transmission), 6=road speed,
7=demand speed, 8=demand speed
CC+, 9=AGS2 transmiss. temp
indication lamp, 10=FUSO Accelerator
PWM output
All information subject to change without notice.