![Detroit Diesel DDEC VI Application And Installation Download Page 209](http://html.mh-extra.com/html/detroit-diesel/ddec-vi/ddec-vi_application-and-installation_2488033209.webp)
DDEC VI ELECTRONIC CONTROLS APPLICATION AND INSTALLATION
4.4
ANALOG OUTPUTS – CPC
The CPC has two analog outputs that can be used for various functions.
4.4.1
PIN 3/05 – ANALOG OUTPUT
This pin can be con
fi
gured for the functions listed in Table 4-47.
Function
Description
Option
Oil Pressure Lamp
This output will be turned on when MCM detects a pre-warning
or warning based on oil pressure.
1
5 Bar Oil Pressure Gauge
The oil pressure will be converted to the proper pulse
width for a 5 Bar Oil Pressure Gauge.
2
10 Bar Oil Pressure Gauge
The oil pressure will be converted to the proper pulse width
for a 10 Bar Oil Pressure Gauge.
3
Table 4-47
Analog Output Selections for CPC Pin 3/05
4.4.2
PIN 3/06 – ANALOG OUTPUT
This pin can be con
fi
gured for the functions listed in Table 4-48.
Function
Description
Option
Coolant Temp Lamp
This output will be turned on when MCM detects a pre-warning
or warning based on coolant temperature.
1
Coolant Temperature Gauge
The coolant temperature will be converted to the proper
pulse width for a coolant temperature gauge.
2
OI Thermostat
Can be used for the input for the OI thermostat.
3
Table 4-48
Analog Output Selections for CPC Pin 3/06
All information subject to change without notice.
(Rev. 01/07)
4-49
7SA827 0701
Copyright © 2007 DETROIT DIESEL CORPORATION