The Cruise Switch PTO parameters are listed in Table 5-73 and Table 5-74.
Parameter
Group
Parameters
Description
Options
Default
Access
0 – Disabled
1 – Enabled
2 – Enabled if neutral
3 – Enabled if neutral and
park brake
4 – Enabled if park brake
7
Con
fi
g PTO
Speed Control
Enables/disables
the PTO function
5 – PTO while driving
0 – Disabled
DDDL
7.0,
DRS,
VEPS
7
Max PTO Spd
Resume Accel
Sw
Sets the max PTO
speed
500 – 3000 RPM
3000 RPM
DDDL
7.0,
DRS,
VEPS
7
Min PTO Spd
Set Coast Sw
Sets the min PTO
speed
500 – 3000 RPM
500 RPM
DDDL
7.0,
DRS,
VEPS
7
PTO Throttle
Override
Enable
Enables/disables
the throttle pedal
from overriding
PTO mode.
0 = Disabled
1 = Enable engine speed in
PTO mode to be increased
with throttle input
1 = Enable
DDDL
7.0,
DRS,
VEPS
7
Throttle
Override Max
Eng Spd
Sets the max
engine speed that
the throttle can
obtain when in
PTO mode.
0 – 3000 RPM
3000 RPM
DDDL
7.0,
DRS,
VEPS
0 – No PTO dropout with
Service Brake or Park
Brake activation
1 – PTO drops out on
Service Brake or Park
Brake activation
2 – PTO drops out on
Service Brake activation
7
PTO Dropout
Serv Brk Prk
Brk
Enables/Disables
the status of the
Service Brake or
Park Brake for
disabling of PTO
3 – PTO drops out on Park
Brake activation
0 = No PTO
dropout with
Service Brake
or Park Brake
activation
DDDL
7.0,
DRS,
VEPS
7
PTO Dropout on
Clutch Enabled
Enables/Disables
the status of the
Clutch Switch for
disabling of PTO
0 – No PTO dropout with
clutch pedal
1 – Causes PTO to dropout
if the clutch is pressed
0 = No PTO
dropout with clutch
pedal
DDDL
7.0,
DRS,
VEPS
Table 5-73
Cruise Switch PTO Parameters (1 of 2)