INPUTS AND OUTPUTS
4.3.17
RED STOP LAMP
The Red Stop Lamp (RSL) is illuminated for all active serious faults, which require the engine to
be shutdown immediately. The AWL will also
fl
ash when an engine shutdown occurs.
Installation
This digital output circuit is designed to sink no more than 250 mA (DC) current.
The RSL is wired to pin 3/16 of the CPC.
NOTE:
This digital output is REQUIRED.
4.3.18
STARTER LOCKOUT
This digital output drives a normally closed relay which interrupts the starting signal when the
output has been activated.
Installation
This digital output circuit is designed to sink no more than 2.0 A (DC) current.
The Starter Lockout digital output is wired to pin 3/17 of the CPC.
Programming Requirements and Flexibility
The options for this digital output are listed in Table 4-42.
Parameter
Group
Parameter
Setting
Options
Default
Access
35
3 17 DO
Selection
1 – Enable Starter
Lockout
0 – Disabled
1 – Enable Starter Lockout
2 – Enable Kickdown Output*
3 – Not Used
4 – Optimized Idle Alarm
5 – Split Valve*
6 – Starter Lockout and AGS2
Run Signal/Starter Lockout
7 – Engine Brake Disabled for
Overspeed*
0 – Disabled
VEPS or
DRS
35
3 17
DO Fault
Detection
—
0 — Disabled
1 — Enabled
0 – Disabled
VEPS or
DRS
* Not supported in NAFTA
Table 4-42
Starter Lockout Programming Options
4-44
All information subject to change without notice.
(Rev. 01/07)
7SA827 0701