![Detroit Diesel DDEC VI Application And Installation Download Page 435](http://html.mh-extra.com/html/detroit-diesel/ddec-vi/ddec-vi_application-and-installation_2488033435.webp)
DDEC VI ELECTRONIC CONTROLS APPLICATION AND INSTALLATION
IO — Idle Operation
Transmission Rate :
On Request
Data Length:
8 bytes
Data Page:
0
PDU format:
254
PDU speci
fi
c:
220
Default priority:
6
PGN:
65,244 (0x00FEDC)
Bytes: 1-4
Total Idle Fuel Used (SPN 236)
Resolution:
0.5 L / Bit, 0 L offset
Bytes: 5-8
Total Idle Hours (SPN 235)
Resolution:
0.05 hr / Bit, 0 hr offset
LFC – Fuel Consumption (Liquid)
Transmission Rate:
On Request
Data Length:
8 Bytes
Data Page:
0
PDU Format:
254
PDU Speci
fi
c:
233
Default Priority:
6
PGN:
65,257 (0x00FEE9)
Bytes: 1–4
Trip Fuel (SPN 182)
Resolution: 0.05 L/bit, 0 L/bit offset
Bytes: 5–8
Total Fuel Used (SPN 250)
Resolution: 0.05 L/bit, 0 L/bit offset
All information subject to change without notice.
(Rev. 01/07)
6-59
7SA827 0701
Copyright © 2007 DETROIT DIESEL CORPORATION