![Detroit Diesel DDEC VI Application And Installation Download Page 326](http://html.mh-extra.com/html/detroit-diesel/ddec-vi/ddec-vi_application-and-installation_2488033326.webp)
FEATURES
MCM Setting
CPC Setting
DPF Manual Regen Only Enable – Disabled
DPF Stationary Regen Only – 1 Enabled
DPF Manual Regen Only Enable - Enabled
DPF Stationary Regen Only – 0 Disabled
DPF Stationary Regen Only – 1 Enabled
Table 5-63
Parked Regeneration Options
There are two CPC options:
□
DPF Stationary Regen Only = 0–Disabled
□
DPF Stationary Regen Only = 1–Enabled
DPF Stationary Regen Only = 0-Disabled
– This option allows the DPF Regeneration Switch
to request a parked regeneration or an over the road regeneration. If the conditions are met
(refer to section 5.19.1) a parked regen will be initiated. If the conditions are not met then an
over-the-road regeneration will occur.
DPF Stationary Regen Only = 1-Enabled
– This option allows the DPF Regeneration Switch to
only request a parked regeneration. If the conditions are met (refer to section 5.19.1) a parked
regen will be initiated. If conditions are not met, nothing will happen.
5-114
All information subject to change without notice.
(Rev. 01/07)
7SA827 0701
Copyright © 2007 DETROIT DIESEL CORPORATION