![Detroit Diesel DDEC VI Application And Installation Download Page 188](http://html.mh-extra.com/html/detroit-diesel/ddec-vi/ddec-vi_application-and-installation_2488033188.webp)
INPUTS AND OUTPUTS
Parameter
Group
Parameter
Options
Default
Access
13
CC On Off Switch Con
fi
g
0 - Hardwired
1 – CCVS1
2 – CCVS2
3 – CCVS3
0
VEPS,
DRS
13
CC Set Cst Res Accel
Sw Con
fi
g
0 - Hardwired
1 – CCVS1
2 – CCVS2
3 – CCVS3
0
VEPS,
DRS
13
Service Brake Switch Con
fi
g
0 - Hardwired
1 – CCVS1
2 – CCVS2
3 – CCVS3
0
VEPS,
DRS
13
Park Brake Switch Con
fi
g
0 - Hardwired
1 – CCVS1
2 – CCVS2
3 – CCVS3
0
VEPS,
DRS
13
Clutch Switch Con
fi
g
0 - Not Con
fi
gured
1 – 1 Clutch Switch
2 – 2 Clutch Switch*
3 – CCVS1
4 – CCVS2
5 – CCVS3
6 – ETC1
0
VEPS,
DRS
13
2nd Axle Speed Switch Con
fi
g
0 - Hardwired
1 – CCVS1
2 – CCVS2
3 – CCVS3
0
VEPS,
DRS
13
Engine Brake Switch Con
fi
g
0 — Hardwired
1 — Info from J1939
255 — Not Available
0
VEPS,
DRS
13
Trans Neutral Input Con
fi
g
0 — Hardwired
1 — Info from J1939
255 — Not Available
0
VEPS,
DRS
13
CC Pause Switch Con
fi
g
0 - Disabled
1 – CCVS1
2 – CCVS2
3 – CCVS3
4 – CCVS1 or CCVS2
5 – CCVS2 or CCVS3
6 – CCVS1 or CCVS3
7 — CCVS1 or CCVS2
or CCVS3
0
VEPS,
DRS
13
Cab PTO Switch Con
fi
g
0 - Hardwired
1 – CCVS1
2 – CCVS2
3 – CCVS3
4 – CCVS1 or Hardwired
5 – CCVS2 or Hardwired
6 – CCVS1 or Hardwired
0
VEPS,
DRS
* Not supported in NAFTA
Table 4-25
Parameters for Multiplexing
4-28
All information subject to change without notice.
(Rev. 01/07)
7SA827 0701