![Detroit Diesel DDEC VI Application And Installation Download Page 444](http://html.mh-extra.com/html/detroit-diesel/ddec-vi/ddec-vi_application-and-installation_2488033444.webp)
COMMUNICATION PROTOCOLS
Shutdown — Idle Shutdown
Transmission Rate :
1 sec
Data Length:
8 bytes
Data Page:
0
PDU format:
254
PDU speci
fi
c:
228
Default priority:
6
PGN:
65,252 (0x00FEE4)
Byte: 1
Idle Shutdown_1
Bits: 8,7
Idle Shutdown Timer State (SPN 590)
00: Inactive
01: Active
Bits: 6,5
Idle Shutdown Timer Override (SPN 592)
00: Inactive
01: Active
Bits: 4,3
Driver Alert Mode (SPN 594)
00: Inactive
01: Active
Bits: 2,1
Engine Has Shutdown by Idle Shutdown (SPN
593)
00: Engine has not shutdown by idle shutdown
01: Engine has shutdown by idle shutdown
Byte: 2
Idle Shutdown_2
Bits: 8,7
Idle Shutdown Timer Function (SPN 591)
00: Disabled in Calibration
01: Enabled in Calibration
Bits: 6-1
Not De
fi
ned
Byte: 3
Bits: 8,7
Not De
fi
ned
Bits: 6,5
Refrigerant High Pressure Switch- N/A
Bits: 4,3
Refrigerant Low Pressure Switch- N/A
Bits: 2,1
A/C High Pressure Fan Switch (SPN 985)
00: Pressure Normal
01: Pressure High Fan May be Engaged
Byte: 4
Lamp_commands
Bits: 2, 1
Wait to Start Lamp (SPN 1081)
00: Inactive
01: Active
Byte: 5
Engine Shutdown_1
Bits: 8,7
Engine Protection System Timer State (SPN 1107)
00: Timer not Active
01: Timer Active
Bits: 6,5
Engine Protection System Timer Override (SPN
1108)
6-68
All information subject to change without notice.
(Rev. 01/07)
7SA827 0701