INPUTS AND OUTPUTS
4.3.3
AGS2 TRANS TEMP LAMP
This digital output is used for non-multiplexed applications with the AGS2 transmission.
Installation
This digital output circuit is designed to sink no more that 250 mA (DC) current.
The AGS2 Transmission Temp Indication Lamp is wired to pin 3/10 of the CPC.
Programming Requirements and Flexibility
The options for this digital output are listed in Table 4-30.
Parameter
Group
Parameter
Setting
Options
Default
Access
35
3 10 DO
Selection
2 – AGS2
Transmission Temp
Indication Lamp
0 – Disabled
1 – Air Filter Lamp*
2 – AGS2 Transmission
Temp Indication Lamp
3 – Battery Voltage Low
Lamp
4 – Coolant Level Low Lamp
5 – FUSO Retarder Control
1*
0 – Disabled
VEPS or
DRS
35
3 10
DO Fault
Detection
—
0 – Disabled
1 – Enable
0 – Disabled
VEPS or
DRS
* Not supported in NAFTA
Table 4-30
AGS2 Transmission Temp Indication Lamp Programming Options
4.3.4
AMBER WARNING LAMP
The Amber Warning Lamp is illuminated for all active faults. The AWL will also
fl
ash when
an engine shutdown occurs.
Installation
This digital output circuit is designed to sink no more than 250 mA (DC) current.
The AWL is wired to pin 2/10 of the CPC.
NOTE:
This digital output is REQUIRED.
4-32
All information subject to change without notice.
(Rev. 01/07)