![Detroit Diesel DDEC VI Application And Installation Download Page 462](http://html.mh-extra.com/html/detroit-diesel/ddec-vi/ddec-vi_application-and-installation_2488033462.webp)
APPENDIX C: PARAMETER LIST
Diagnostic
Name
Parameter
Group
Min
Max
Default
Access
Range
3 07 DO
Selection
35
0
5
0
DRS, VEPS
0=disabled, 1=decompression valve,
2=grid heater, 3=TOP2 lockout
solenoid, 4=modulation output for
Allison Transmission without J1939
Interface (Gear1), 5=PTO valve for
AGS2
3 08 DO Fault
Detection
35
0
1
0
DRS, VEPS
0=disabled, 1=enabled
3 08 DO
Selection
35
0
7
0
DRS, VEPS
0=disabled, 1=exhaust brake only,
2=exhaust and decompression brake
via single valve, 3=port extension turbo
brake, 4=PTO stationary for AGS2,
5=PTO mobile for AGS2, 6=TOP2 shift
solenoid, 7=Fuso starter lockout relay
3 09 DO Fault
Detection
35
0
1
0
DRS, VEPS
0=disabled, 1=enabled
3 09 DO
Selection
35
0
5
0
DRS, VEPS
0=disabled, 1=grid heater hardwired,
2=AGS2 backup lamp, 3=engine brake
active, 4=not used, 5=FUSO engine
brake active lamp
3 10 DO Fault
Detection
35
0
1
0
DRS, VEPS
0=disabled, 1=enabled
3 10 DO
Selection
35
0
5
0
DRS, VEPS
0=disabled, 1=air
fi
lter lamp, 2=AGS2
transmiss. temp indication lamp,
3=battery voltage low lamp, 4=coolant
level low lamp, 5=Fuso retarder control
1
3 12 DO Fault
Detection
35
0
1
0
DRS, VEPS
0=disabled, 1=enabled
3 12 DO
Selection
35
0
5
0
DRS, VEPS
0=disabled, 1=oil level lamp, 2=AGS2
check transmiss. indication lamp OI:
Optimized Idle, 3=oil pressure low lamp,
4=cruise / Pressure Governor System
active lamp, 5=Fuso retarder control 2
3 17 DO Fault
Detection
35
0
1
0
DRS, VEPS
0=disabled, 1=enabled
3 17 DO
Selection
35
0
7
0
DRS, VEPS
0=disabled, 1=enable starter lockout,
2=enable kick down output, 3=not used,
4=optimized idle alarm, 5=split valve 2,
6=starter lockout and AGS2 run signal /
starter lockout, 7=engine brake disabled
for over speed
3 18 DI
Selection
13
0
10
0
DRS, VEPS
0=disable, 1=enable ABS input,
2=enable transmission retarder input,
3=enable tempo set, 4=enable grid
heater detection, 5=switchable torque
demand, 6=drive on super structure,
7=throttle inhibit super structure, 8=split
select, 9=FUSO Engine brake stage 2
cancel switch, 10=DPF inhibit switch
C-2
All information subject to change without notice.
(Rev. 01/07)
7SA827 0701
Copyright © 2007 DETROIT DIESEL CORPORATION