DDEC VI ELECTRONIC CONTROLS APPLICATION AND INSTALLATION
4.1.18
REGEN SWITCH
The Regen Switch is used by the operator to initiate a parked regeneration. If “DPF J1939 Regen
SW Enable” is active, the CPC will no longer process the hardwired DPF Regen Switch requests.
The CPC must receive regular periodic switch status messages over J1939.
The Regen Switch is a momentary normally open switch. Refer to section 5.19 for additional
information.
Installation
The Regen Switch is wired to the CPC #4 connector pin 4/17. A switch is required or wiring
must be available to connect an external switch.
Programming Requirements and Flexibility
The options for this digital input are listed in Table 4-17.
Parameter
Group
Parameter
Options
Default
Access
13
4 17 DI Selection
0 – Disable
1 – 2 Clutch Switch*
2 – DPF Regeneration Switch
3 — FUSO Air Suspension Speed Limit
Switch*
2 – DPF
Regeneration
Switch
VEPS or
DRS
46
DPF J1939 Regen
Sw Enable
0 – Not Active
1 – Active
0 – Not Active
VEPS or
DRS
* Not supported in NAFTA
Table 4-17
Regen Switch Programming Options
All information subject to change without notice.
(Rev. 01/07)
4-19