![Detroit Diesel DDEC VI Application And Installation Download Page 449](http://html.mh-extra.com/html/detroit-diesel/ddec-vi/ddec-vi_application-and-installation_2488033449.webp)
DDEC VI ELECTRONIC CONTROLS APPLICATION AND INSTALLATION
TCO1 — Tachograph
Reception Rate :
50 ms
Data Length:
8
Data Page:
0
PDU format:
254
PDU speci
fi
c:
108
Default priority:
3
PGN:
65,132 (0x00FE6C)
Byte : 1
Driver Status
Bits: 7,8
Drive Recognize (SPN 1611) – N/A
Bits: 4–6
Driver 2 Working State (SPN 1613) – N/A
Bits: 1–3
Driver 1 Working State (SPN 1612) – N/A
Byte: 2
Driver 1
Bits: 7,8
Overspeed (SPN 1614) – N/A
Bits: 4–6
Driver card, Driver 1 (SPN 1615) – N/A
Bits: 1–3
Driver 1 Time Related States (SPN 1617) – N/A
Byte: 3
Driver 2
Bits: 7,8
Not De
fi
ned
Bits: 5,6
Driver card, driver 2 (SPN 1616) – N/A
Bits: 1–4
Driver 2 Time Related States (SPN 1618) – N/A
Byte: 4
TCO1 Information
Bits: 7,8
Direction Indicator (SPN 1619) – N/A
Bits: 5,6
Tachograph Performance (SPN 1620) – N/A
Bits: 3,4
Handling Information (SPN 1621) – N/A
Bits: 1,2
System Event (SPN 1622) – N/A
Bytes: 5,6
Tachograph Output Shaft Speed (SPN 1623)
Resolution:
0.125 rpm/bit, 0 offset
Bytes: 7,8
Tachograph Vehicle Speed (SPN 1624)
Resolution:
1/256 km/h per bit, 0 offset