![Detroit Diesel DDEC VI Application And Installation Download Page 123](http://html.mh-extra.com/html/detroit-diesel/ddec-vi/ddec-vi_application-and-installation_2488033123.webp)
DDEC VI ELECTRONIC CONTROLS APPLICATION AND INSTALLATION
Shrink Wrap
Shrink wrap is required when splicing non insulated connections. Raychem HTAT or any
equivalent heat shrink dual wall epoxy encapsulating adhesive polyole
fi
n is required. Shrink wrap
must extend at least .25 in. (6 mm) over wire insulation past splice in both directions.
Alpha Wire Corporation
Tyco Electronics Corporation
711 Lidgerwood Ave
Raychem Cable Identi
fi
cation and Protection
P.O. Box 711
300 Constitution Drive
Elizabeth, New Jersey 07207-0711
Menlo Park, CA 94025
1-800-52ALPHA
Phone: 1–800–926–2425
www.alphawire.com
www.raychem.com
To heat shrink wrap a splice:
NOTICE:
The heat shrink wrap must overlap the wire insulation about .25
in. (6 mm) on both sides of the splice.
1. Select the correct diameter to allow a tight wrap when heated.
2. Heat the shrink wrap with a heat gun; do not concentrate the heat in one location, but
apply the heat over the entire length of shrink wrap until the joint is complete.
3. Repeat step 2 to apply a second layer of protection (if required by splicing guidelines).
All information subject to change without notice.
(Rev. 01/07)
3-85
7SA827 0701
Copyright © 2007 DETROIT DIESEL CORPORATION