![Detroit Diesel DDEC VI Application And Installation Download Page 237](http://html.mh-extra.com/html/detroit-diesel/ddec-vi/ddec-vi_application-and-installation_2488033237.webp)
DDEC VI ELECTRONIC CONTROLS APPLICATION AND INSTALLATION
CPC
Parameter
Group
Parameter
Description
Options
Setting
Access
13
Engine Brake
Switch Con
fi
g
—
0 = Hardwired
1 = Info from J1939
255 = Not Available
0 = Hard-
wired
VEPS or
DRS
13
J1939 Steps
Engine Brake
—
0 = Variable Controlled Brake
1 = 1 Step
2 = Low/High Steps
3 = Low/Med/High Steps
255 = Not Con
fi
gured
1 = 1 Step
VEPS or
DRS
13
J1939 Engine
Retarder
Con
fi
g
—
3 = Jake or Constant Throttle Brake
4 = Exhaust Flap
255 = Not Con
fi
gured
4 =
Exhaust
Flap
VEPS or
DRS
Table 5-13
CPC Con
fi
guration Parameter for Exhaust Flap Applications -
MBE900 Engine
See Figure 5-6 for the MBE900 exhaust
fl
ap only schematic.
Figure 5-6
Exhaust Flap Only – MBE900
All information subject to change without notice.
(Rev. 01/07)
5-25
7SA827 0701
Copyright © 2007 DETROIT DIESEL CORPORATION