![Detroit Diesel DDEC VI Application And Installation Download Page 207](http://html.mh-extra.com/html/detroit-diesel/ddec-vi/ddec-vi_application-and-installation_2488033207.webp)
DDEC VI ELECTRONIC CONTROLS APPLICATION AND INSTALLATION
4.3.21
VEHICLE POWER SHUTDOWN
This digital output actuates a relay that shuts down the rest of the electrical power to the vehicle
when an idle shutdown or engine protection shutdown occurs.
Installation
The Vehicle Power Shutdown is wired to pin 4/10 of the CPC. This is a high side digital output.
Programming Requirements and Flexibility
The options for this digital output are listed in Table 4-45.
Parameter
Group
Parameter
Setting
Options
Default
Access
35
4 10 DO
Selection
3 — Vehicle Power
Shutdown
0 — Disable
3 — Vehicle Power
Shutdown/Ignition Relay
0 — Disable
VEPS or
DRS
35
4 10 DO Fault
Detection
—
0 — Disabled
1 — Enabled
0 — Disable
VEPS or
DRS
Table 4-45
Vehicle Power Shutdown Programming Options
All information subject to change without notice.
(Rev. 01/07)
4-47
7SA827 0701
Copyright © 2007 DETROIT DIESEL CORPORATION