12. Diagnostics and Troubleshooting
Operation and Installation Manual for SOLIVIA 2.0/2.5/3.0/3.3/3.6/5.0 EU G4 TR
76
12.4.4 "Change Events" Log
Menu
482 Change events
Description
The log contains a chronological list of all changes that affect
energy production and thereby profit.
Change events can be made on the display, via the service soft-
ware or by a ripple control signal.
Accessing the Menu
Main Menu > Production Info > Event Journal > Change
Events
➔
USB features
Options
Install settings
Production info
Diagnostic&Alarm
SOLIVIA ##
1. In the main menu, press the
buttons to select
Produc-
tion Info
and then press the
button.
➔
Year statistics
Total statistics
Feed-in settings
Event journal
History
400 Production info
2. Press the
buttons to
select
(Event Journal
Change
Events) and then press the
button.
➔
-------------------
Change events
External events
-------------------
480 Event journal
3. Press the
buttons to se-
lect
Change Events
and then
press the button.
Max power: 90%
Max power: 100%
16.04.12 17:25:36 S
482 Change events
4. You can view the whole list by
pressing the
buttons.
Message Structure
Each message consists of three lines defined as follows:
Max power: 90%
Max power: 100%
16.04.12 17:25:36 S
482 Change events
1st Line
Date and time when the external event
occurred.
Source of the change:
D: Display
E: External (RS485)
U: USB interface
S: System
3rd Line
Name of the changed parameter and
previous value
4th Line
Name of the changed parameter and new
value
12.4.3 Log for VDE AR n 4105
Menu
640 Report LVD
Description
For grids in accordance with VDE AR N4105, the last five failure
messages must be saved in a separate log.
The log is only available fo the grids
DE LVD
and
DK LVD
.
Accessing the Menu
Main menu > Diagnostic&Alarm > Report LVD
➔
USB features
Options
Production info
Diagnostic&Alarm
Inverter info
SOLIVIA ##
1. In the main menu, press
the
buttons to select
Diagnostic&Alarm
and then
press the button.
➔
-------------------
Report LVD
Internal log
-------------------
600 Diagnostic&Alarm
2. Press the
buttons to
select
Report LVD
and then
press the button.
- Critical OverVolt
16.04.2012 17:25:36
▼▼▼▼▼ ERROR 5 ▼▼▼▼▼▼
640 Report LVD
3. You can view the whole list by
pressing the
buttons.
Message Structure
Each message consists of three or more lines defined as follows:
- Critical OverVolt
16.04.2012 17:25:36
▼▼▼▼▼ ERROR 5 ▼▼▼▼▼▼
640 Report LVD
1st Line
Failure number (the higher the number,
the more current the failure)
2nd Line
Date and time when the event occurred.
3rd and Other Lines
Brief description of the failure(s)