10. Settings
Operation and Installation Manual for SOLIVIA 2.0/2.5/3.0/3.3/3.6/5.0 EU G4 TR
54
10.5 Backlighting, contrast
Menu
120 Display settings
Description
Allows backlighting and contrast to be configured.
Accessing the Menu
Main Menu > Install Settings > Display Settings
➔
Options
Install settings
-------------------
SOLIVIA ##
1. In the main menu, press the
buttons to select
Install
Settings
and then press the
button.
➔
Display settings
Date and time
Language: English
-------------------
Grid selection
100 Install settings
2. Press the
buttons to
select
Display Settings
and
then press the button.
➔
Backlight: Auto
Contrast: 10
-------------------
120 Display settings
3. Select a parameter with the
buttons. Press the but-
ton to change the value.
Configurable Parameters
Display Text
Designation
Description
Backlight
Display backlightingAuto | On
Auto = The backlighting
switches on when a display
button is pressed.
On = The backlighting is
always switched on.
Contrast
Display contrast
1 - 10
10.6 RS485 (EIA485) Settings
Menu
140 RS485
Description
Allows the ID and baudrate of the RS485 interface to be configured.
Accessing the Menu
Main Menu > Install Settings > RS485
➔
Options
Install settings
-------------------
SOLIVIA ##
1. In the main menu, press the
buttons to select
Install
Settings
and then press the
button.
➔
Display settings
Date and time
Grid selection
RS485
-------------------
100 Install settings
2. Press the
buttons to
select
RS485
and then press
the button.
➔
Baudrate: 19200
ID: 1
-------------------
140 RS485
3. Select a parameter with the
buttons. Press the but-
ton to change the value.
Configurable Parameters
Display Text
Designation
Description
ID
Solar Inverter Iden-
tification Number
1 - 254
Baudrate
Baudrate
2400 | 4800 | 9600 | 19200
| 38400, the standard is
19200
nOTE
Connecting Multiple Solar Inverters via RS485
► Select a different ID for each solar inverter.
► A termination resistor must be connected
to the last solar inverter in the series (see
“7.5 Connecting RS485 (EIA485) - Optional”,
p. 32
).
► This termination resistor can be ordered from
Delta, see
“16.2 Overview of Menu Struc-
ture”, p. 83
.