12. Diagnostics and Troubleshooting
Operation and Installation Manual for SOLIVIA 2.0/2.5/3.0/3.3/3.6/5.0 EU G4 TR
70
Messages on the current operating status are shown by the LEDs
and text messages on the display in the
411 Current Overview
menu.
When an event occurs, the
411 Current Overview
menu auto-
matically displays.
A brief description of the event is then shown on the fourth display
line.
External events
Day: ____Wh
Now: ____W
411 Current overview
The software of the solar inverter determines whether a warning is
given or a failure occurs.
For problems with the insulation or grounding, you can use the
230
Grounding
menu to define whether a warning is given or a failure
is triggered (see Chapter
“10.13 Insulation and grounding monitor-
ing”, p. 61).
The individual message categories are displayed as follows:
Message Cat-
egory
Message Class
LED Status
Display Text in 411 Current Over-
view Overview
Description
Normal operation –
Operation
Earth Fault
Failure
Normal operation
When the green
O
peratiOn
LED is
solid, the solar inverter is feeding
power into the grid.
Limited operation –
Operation
Earth Fault
Failure
e.g.
self-test
,
synchronization
When the green
O
peratiOn
LED
flashes, the solar inverter is not feed-
ing power into the grid.
External event
Internal event
Warning
Operation
Earth Fault
Failure
For external events:
Ext. events
For internal events:
Warning ###
(3-digit number)
For a warning, the yellow
F
ailure
LED
flashes. The solar inverter continues
to feed power into the grid.
External event
Internal event
Failure
Operation
Earth Fault
Failure
For external events:
Ext. events
For internal failures:
Failure ###
(3-digit number)
For a failure, the yellow
F
ailure
LED is solid. The feed to the grid is
stopped.
Insulation and
grounding failure
Warning
Operation
Earth Fault
Failure
Isolation alarm
For an Isolation alarm, the red
e
arth
F
ault
LED flashes. The solar inverter
continues to feed power into the grid.
Failure
Operation
Earth Fault
Failure
Insulation failure
For an insulation failure, the red
e
arth
F
ault
LED is solid. The feed to the
grid is stopped.
Table 12.2:
Display of message categories on the LEDs and
display