
13
Operation and Installation Manual for SOLIVIA 2.0/2.5/3.0/3.3/3.6/5.0 EU G4 TR
5. Product Description
EN
AC nom.output voltage:
AC nom.output frequency:
AC max. continuous output current:
AC max. continuous output power:
AC power factor
DC operating volt. range:
DC operating volt. range (MPP):
DC max. input voltage:
DC max. operating current:
DC max. current per string:
XX
YYWW
LLLMMMXXYYWWZZZZZZ
www.solar-inverter.com
Designed in: Germany
Made in: production plant
Rev:
Date code:
S/N:
SOLIVIA3.6EUG4
EOE46010316
125-600V
170-480V
600V
22.0A
17A
230V
50Hz
16.0A
3600VA
Cap 0.8~Ind 0.8
VDE 0126-1-1(D)
VDE-AR-N-4105
Country specific standards and settings:
see manual
IP class: IP65
Safety class: 1
Ambient temp: -25°C...+70°C, derating >55°C
Fig. 5.6:
SOLIVIA 3.6 EU G4 TR type plate
AC nom.output voltage:
AC nom.output frequency:
AC max. output current:
AC nom. output power:
DC operating volt. range (MPP):
DC max. input voltage:
DC max. operating current:
DC max. current per string:
XX
YYWW
LLLMMMXXYYWWZZZZZZ
www.solar-inverter.com
Designed in: Germany
Made in: production plant
Rev:
Date code:
S/N:
SOLIVIA5.0EUG4TR
EOE46010253
SN:
LLLMMMXXYYWWZZZZZZ
150-480V
600V
37A
18A
230 220V
50 60Hz
27.2 28.5A
5000W
IEC 60950-1
EN 50178
IEC 62103
IEC 62109-1 and IEC 62109-2
Country specific standards and settings:
see manual
IP class: IP65
Safety class: 1
Ambient temp: -20°C...+70°C, derating >55°C
5min
Fig. 5.7:
SOLIVIA 5.0 EU G4 TR type plate
Meaning of Information on Type Plate
Warning Symbols on Type Plate
Meaning of Warning Symbols
5 min
Risk of death by electrocution
Potentially fatal voltage is present when the solar inverter is in operation that remains for five
minutes after being disconnected from power.
Never open the solar inverter. The solar inverter contains no components that must be main-
tained or repaired by the operator or installer. Opening the cover will void the warranty.
Read the manual before working with the solar inverter and follow the instructions contained in
the manual.
Risk of injury from high temperatures
When in operation, the housing of the solar inverter can become very hot.
Only touch the housing of the solar inverter (outside of the control panel) with safety gloves.
The control panel itself is protected by a special surface.
DC operating volt. range
DC operating volt. range
DC operating volt. range (MPP)
DC operating volt. range (MPP)
DC max. input voltage
DC max. input voltage
DC max. operating current
DC max. operating current
DC max. current per string
DC max. current per string
AC nom. output voltage
AC nom. output voltage
AC nom. output frequency
AC nom. output frequency
AC max. continuous output current
AC max. continuous output current
AC max. continuous output power
AC max. apparent power
AC power factor
AC power factor (cos φ)
IP class
IP class
Safety class
Safety class
Ambient temperature/derating
Ambient temperature/derating