Chapter 4 Display and Operation
ASDA-A User Manual
4th Edition 2005/11/30, HE03
© DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED
4-10
4-4-6 DO signal Display Diagnosis Operation
Follow the setting method in Figure 4.8 to enter into DO signal display diagnosis operation mode.
According to the ON and OFF status of digital output signals DO1 to DO5, the corresponding signal status
will display on the LED display. When the segment lit and display on the screen, it means that the digital
input signal is ON. (Please also refer to Figure 4.8)
Figure 4.8
ON
DO10 DO9 DO8
DO5DO4 DO3 DO2 DO1
ON
ON
ON
ON
OFF
OFF
OFF OFF OFF
SET
Light: