Chapter 7 Parameters
ASDA-A User Manual
4th Edition 2005/11/30,
HE03
© DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED
7-66
Sign
Setting
Value
DI Function Description
STEPD 40
Step down input. When STEPD is
activated, the motor will run to previous
position.
STEPB 41
Step back input. When STEPB is
activated, the motor will return to first
position.
AUTOR 42
Auto run input. When AUTOR is
activated, the motor will run
automatically according to internal
position command. For time interval
setting, please see P2-52 to P2-59.
Available when the drive is in Pr mode and
users must set P1-33 to 5 and 6. (Internal auto
running mode) [see section 12-7 Internal Auto
Running Mode]
GNUM0
43
Electronic gear ratio (Numerator) selection 0 [see P2-60~P2-62]
GNUM1
44
Electronic gear ratio (Numerator) selection 1 [see P2-60~P2-62]
INHP 45
Pulse inhibit input. When the drive is in position mode, if INHP is activated, the
external pulse input command is not valid.
Note:
1. 11~17: Single control mode, 18~20: Dual control mode
2. When P2-10 to P2-17 is set to 0, it indicates input function is disabled.