ASDA-A User Manual
Chapter 3 Configuration and Wiring
© DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED
4th Edition 2005/11/30, HE03
3-23
Setting of parameter P2-10 to P2-17:
Setting of parameter P2-18 to P2-22:
DI
Code
Signal
Description
DO
Code
Signal
Description
01
SON Servo On
01
SRDY Servo ready
02 ARST
Reset
02 SON
Servo
On
03 GAINUP
Gain switching in speed and
position mode
03 ZSPD Zero
speed
04
CCLR Pulse clear (see P2-50)
04
TSPD Speed reached
05
ZCLAMP Low speed CLAMP
05
TPOS Positioning completed
06
CMDINV Command input reverse control
06
TQL
Reached torques limits
07 HOLD
Internal position control command
pause
07
ALRM Servo alarm output (Servo fault)
08 CTRG
Command triggered (available in P
mode only)
08 BRKR Electromagnetic
brake
09
TRQLM Torque limit enabled
09
HOME Home completed
10
SPDLM Speed limit enabled
10
OLW Output overload warning
11
POS0 Position command selection (1~8)
12
POS1 Position command selection (1~8)
13
POS2 Position command selection (1~8)
14
SPD0 Speed command selection (1~3)
15
SPD1 Speed command selection (1~3)
16
TCM0 Torque command selection (1~3)
17
TCM1 Torque command selection (1~3)
18 S-P
Position / Speed mode switching
(OFF: Speed, ON: Position)
19 S-T
Speed / Torque mode switching
(OFF: Speed, ON: Torque)
20 T-P
Torque / Position mode switching
(OFF: Torque, ON: Position)
21
EMGS Emergency stop (contact b)
22
CWL Reverse inhibit limit (contact b)
23
CCWL Forward inhibit limit (contact b)
24
ORGP Reference “Home” sensor
25 TLLM
Reverse operation torque limit
(Torque limit function is valid only
when P1-02 is enabled)
26 TRLM
Forward operation torque limit
(Torque limit function is valid only
when P1-02 is enabled)
27
SHOM Move to “Home”
28
INDEX0 Feed step selection input 0 (bit 0)
29
INDEX1 Feed step selection input 1 (bit 1)
30
INDEX2 Feed step selection input 2 (bit 2)
31
INDEX3 Feed step selection input 3 (bit 3)
32
INDEX4 Feed step selection input 4 (bit 4)